Hexanol, N- Chemical Storage Specifications

Compliant storage and rental solutions for Hexanol, N- (C₆H₁₄O). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Hexanol, N-

Hexanol is a colorless liquid with a fruity odor. It is used as a flavoring additive, as an insecticide, in the processing of leather, and in the manufacture of antiseptics, perfumes, plasticizers and other chemicals. * n-Hexanol is on the Hazardous Substance List because it is cited by DOT and NFPA.

Structured hazard data

Hazard class
Category 2 Flammable Liquid
Storage category
Flammable Storage
Flammable
Yes
Flash point
59 °C / 138.2 °F
Storage temperature
4 C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Flammable and/or toxic gases are generated by the combination of alcohols with alkali metals, nitrides

Acute oral toxicity Category 4 Acute dermal toxicity Category 4 Serious Eye Damage/Eye Irritation Category 2

Fire Suppression System

Dry Chemical fire suppression is recommended for Hexanol, N-

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Hexanol, n- (C₆H₁₄O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Hexanol, n- should account for its listed hazards (Category 2 Flammable Liquid), climate control needs (4 C), and segregation requirements. Flammable and/or toxic gases are generated by the combination of alcohols with alkali metals, nitrides

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Physical State Liquid Appearance Colorless Odor sweet Odor Threshold 10 ppm pH Not applicable Melting Point/Range -52 °C / -61.6 °F Boiling Point/Range 156 - 157 °C / 312.8 - 314.6 °F Flash Point 59 °C / 138.2 °F Method - DIN 51758 Evaporation Rate No information available Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 7.7 vol % Lower 1.2 vol % Vapor Pressure 1.3 mbar @ 20 °C Vapor Density 3.52 Specific Gravity 0.814 Solubility No information available Partition coefficient; n-octanol/water No data available Autoignition Temperature 292 °C / 557.6 °F Decomposition Temperature No information available Viscosity 5.3 mPa.s at 20 °C Molecular Formula C6 H14 O Molecular Weight 102.18

Matched to this chemical

Recommended storage solutions for Hexanol, N-

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Hexanol, n- be stored?

Store Hexanol, n- in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Category 2 Flammable Liquid). Climate range guidance: 4 C. Compatibility notes: Flammable and/or toxic gases are generated by the combination of alcohols with alkali metals, nitrides US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Hexanol, n- flammable?

Yes — Hexanol, n- is flagged as a flammable hazard in this database (Yes). Flash point: 59 °C / 138.2 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Hexanol, n-?

Hexanol, n- is listed as: Category 2 Flammable Liquid. Acute oral toxicity Category 4 Acute dermal toxicity Category 4 Serious Eye Damage/Eye Irritation Category 2

What fire suppression is recommended for Hexanol, n-?

Dry Chemical fire suppression is generally recommended for Hexanol, n- (C₆H₁₄O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Hexanol, n- storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Hexanol, n-. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.